Fuel Forensics
The Case of the Washed-Out Labels
A storm flooded a busy port depot. Eight crates of fuel survived, but every label washed off. You are the inspector. Read the evidence, relabel the crates, follow crude oil through a refinery, send each fuel to the right job and audit a cogeneration plant.
Name eight unlabeled samples from tests, then climb the coal ladder.
Label the tower, calculate gallons, order the oil sands steps.
Match eight jobs with ten fuels and compare CO₂ per Btu.
Capture waste heat and find the fuel you can save.
Before you start
Inspector name Team
All sample readings are typical values, rounded and approximate. Real fuels vary by deposit. Cogeneration numbers are illustrative: values are hypothetical. Nothing you type is saved or sent anywhere.
Round 1 · Lab Bench
Tap a crate to open it. State, look and burn test are free. Moisture, carbon and heat-content tests cost a token, and you have 12 for all eight crates (). Reveal at least two clues for a crate, then choose its label. Fewer tokens used means a more efficient inspector.
Evidence graph
Round 2 · Refinery Run
Crude oil is heated in a furnace, and the vapors rise up the tower. Each cut condenses at its own height: the coolest, lightest cuts leave at the top and the heaviest stay at the bottom.
How many gallons?
One barrel is 42 gallons. A barrel of crude yields about 19 gal gasoline, 12 gal diesel and heating oil, 4 gal jet fuel, plus other products. Source: U.S. EIA, typical U.S. refinery, rounded and approximate.
Barrels per day: 5,000
At 5,000 barrels a day, how many gallons per day? Gasoline Diesel Jet fuel
Oil sands: put the steps in order
Oil sands hold bitumen, a thick, tar-like oil. Use the arrows to put the four steps in order.
Compared with conventional crude, oil sands cost more energy, water and land per barrel. Heating deep deposits takes a lot of steam, and steam is usually made by burning fuel.
Round 3 · Dispatch
Eight jobs are waiting. Tap the best fuel for each one. A wrong choice is crossed out with a hint, so use the property, not a guess. The chart shows CO₂ released per million Btu burned. Source: U.S. EIA emission factors, rounded.
CO₂ per million Btu
Think
Anthracite burns with very little smoke. Does that make it low in CO₂?
Round 4 · Cogeneration Audit
A normal power plant turns only about 35% of its fuel energy into electricity; the rest leaves as waste heat. A combined heat and power (CHP) plant captures that heat and uses it. Illustrative data: values are hypothetical. Units of fuel = million Btu per hour.
Predict first
Boiler fuel for 45 units of heat at 90% = 45 ÷ 0.90 = units
Separate total (100 for the power plant + boiler) = units
Separate efficiency, (35+45) ÷ total × 100 = %
CHP efficiency, (35+45) ÷ 100 × 100 = %
Fuel saved by CHP = units CO₂ saved at 53 kg per MMBtu = kg per hour
Try your own site
Electricity needed 35 units Heat needed 45 units
Two real-sized sites
| Site A: hospital and campus (70 electricity, 90 heat) | Site B: paper mill (105 electricity, 135 heat) | |
|---|---|---|
| Fuel saved by CHP (units) | ||
| CO₂ saved (kg per hour) |
Hint: separate = electricity ÷ 0.35 + heat ÷ 0.90; CHP = (electricity + heat) ÷ 0.80.
Site C
A power plant stands 40 km from the nearest town, with no factories or buildings next to it. Should it add a CHP system?
Inspector's Report
Exit question
Explain why a cogeneration plant burns less fuel than separate plants making the same electricity and heat. Identify one condition that limits where cogeneration can be used.