Free to play, no login. Want the full activity with student pages and answer key?Get it on TpT More free simulations
Fuel ForensicsGREEN FLASK SCIENCE™ · UNIT 6 · TOPIC 6.3
Oil refinery at dusk
Case file

Fuel Forensics

The Case of the Washed-Out Labels

A storm flooded a busy port depot. Eight crates of fuel survived, but every label washed off. You are the inspector. Read the evidence, relabel the crates, follow crude oil through a refinery, send each fuel to the right job and audit a cogeneration plant.

Open-pit coal mine
1 Lab Bench
Name eight unlabeled samples from tests, then climb the coal ladder.
Refinery
2 Refinery Run
Label the tower, calculate gallons, order the oil sands steps.
Stacked firewood
3 Dispatch
Match eight jobs with ten fuels and compare CO₂ per Btu.
Steam plumes at a power plant
4 Cogeneration Audit
Capture waste heat and find the fuel you can save.

Before you start

Inspector name Team

All sample readings are typical values, rounded and approximate. Real fuels vary by deposit. Cogeneration numbers are illustrative: values are hypothetical. Nothing you type is saved or sent anywhere.

Round 1 · Lab Bench

Tap a crate to open it. State, look and burn test are free. Moisture, carbon and heat-content tests cost a token, and you have 12 for all eight crates (). Reveal at least two clues for a crate, then choose its label. Fewer tokens used means a more efficient inspector.

Evidence graph

Dots appear when a crate has both its moisture and heat tests. Turn on the Fuel Files to see typical ranges as shaded boxes.

Round 2 · Refinery Run

Crude oil is heated in a furnace, and the vapors rise up the tower. Each cut condenses at its own height: the coolest, lightest cuts leave at the top and the heaviest stay at the bottom.

How many gallons?

One barrel is 42 gallons. A barrel of crude yields about 19 gal gasoline, 12 gal diesel and heating oil, 4 gal jet fuel, plus other products. Source: U.S. EIA, typical U.S. refinery, rounded and approximate.

Barrels per day: 5,000

At 5,000 barrels a day, how many gallons per day? Gasoline Diesel Jet fuel

Oil sands: put the steps in order

Oil sands hold bitumen, a thick, tar-like oil. Use the arrows to put the four steps in order.

    Compared with conventional crude, oil sands cost more energy, water and land per barrel. Heating deep deposits takes a lot of steam, and steam is usually made by burning fuel.

    Round 3 · Dispatch

    Eight jobs are waiting. Tap the best fuel for each one. A wrong choice is crossed out with a hint, so use the property, not a guess. The chart shows CO₂ released per million Btu burned. Source: U.S. EIA emission factors, rounded.

    Stacked firewoodFirewood stacked to dry. Photo: Horia Varlan, CC BY 2.0
    Blue gas flamesNatural gas flame. Photo: pedrik, CC BY 2.0

    CO₂ per million Btu

    Wood and peat are left off: whether their CO₂ counts depends on how fast the plants regrow.

    Think

    Anthracite burns with very little smoke. Does that make it low in CO₂?




    Round 4 · Cogeneration Audit

    A normal power plant turns only about 35% of its fuel energy into electricity; the rest leaves as waste heat. A combined heat and power (CHP) plant captures that heat and uses it. Illustrative data: values are hypothetical. Units of fuel = million Btu per hour.

    Predict first

    Boiler fuel for 45 units of heat at 90% = 45 ÷ 0.90 = units

    Separate total (100 for the power plant + boiler) = units

    Separate efficiency, (35+45) ÷ total × 100 = %

    CHP efficiency, (35+45) ÷ 100 × 100 = %

    Fuel saved by CHP = units   CO₂ saved at 53 kg per MMBtu = kg per hour

    Try your own site

    Electricity needed 35 units   Heat needed 45 units

    Two real-sized sites

    Site A: hospital and campus (70 electricity, 90 heat)Site B: paper mill (105 electricity, 135 heat)
    Fuel saved by CHP (units)
    CO₂ saved (kg per hour)

    Hint: separate = electricity ÷ 0.35 + heat ÷ 0.90; CHP = (electricity + heat) ÷ 0.80.

    Site C

    A power plant stands 40 km from the nearest town, with no factories or buildings next to it. Should it add a CHP system?




    Case closed

    Inspector's Report

    Exit question

    Explain why a cogeneration plant burns less fuel than separate plants making the same electricity and heat. Identify one condition that limits where cogeneration can be used.

    Image credits

    Data sources

    CO₂ per million Btu: U.S. EIA emission factors, rounded. Refinery yields: U.S. EIA, typical U.S. refinery, rounded. Sample readings and handbook ranges: typical values for classroom use, rounded and approximate. Cogeneration numbers: illustrative data, values are hypothetical.

    Terms of Use

    Free to play and share online. © Green Flask Science™.

    Liked Fuel Forensics?

    The full activity (Topic 6.3) comes with student pages, an answer key and editable files, ready to use with your class.

    Get the full activity on TpTMore Unit 6 simulations

    AP® is a trademark registered by the College Board, which is not affiliated with and does not endorse this product.