AP Chemistry · Unit 9 · Topic 9.9
9.9 Cell Potential and Free Energy
TLDR
A cell's voltage is the gap between two standard reduction potentials: E°cell = E°cathode − E°anode, where the cathode is the half-reaction that is reduced. Voltage is energy per coulomb, so multiplying by the charge that moves gives energy: ΔG° = −nFE°, with n the moles of electrons transferred in the balanced equation and F = 96,485 C/mol e−. A positive E° means a negative ΔG°, a thermodynamically favored reaction and K > 1. E° never changes when you multiply an equation; ΔG° does, because n does.
Guess firstFor Zn(s) + Cu2+(aq) → Zn2+(aq) + Cu(s), E°cell = +1.10 V. A student doubles every coefficient: 2Zn + 2Cu2+ → 2Zn2+ + 2Cu. What happens to E° and ΔG°?
Pick one now. The page tells you if you were right at the end, after the picture and the sim show you why.
A is wrong. Trap: treating E° like an amount. E° is intensive, like temperature; a bigger batch pushes each electron just as hard.
B is wrong. Trap: forgetting that ΔG° is per mole of reaction as written. Twice the reaction moves twice the electrons, so n doubles.
C is correct. Voltage is energy per coulomb, so it does not depend on how much reacts. Doubling the equation doubles the electrons moved (n goes from 2 to 4), so ΔG° = −nFE° goes from −212 kJ to −425 kJ per mole of reaction as written.
D is wrong. Trap: the two are switched. E° is the one that stays put; ΔG° scales with n.
Locked in. Keep reading, the answer is at the end of the page.
The whole topic in one picture
- The voltage is a gap. Cu2+/Cu is +0.34 V and Zn2+/Zn is −0.76 V. The higher one is reduced (cathode) and the lower one runs backward as oxidation (anode): E°cell = E°cathode − E°anode = 0.34 − (−0.76) = +1.10 V. Never add the two values.
- Count the electrons once. Zn → Zn2+ + 2e− and Cu2+ + 2e− → Cu. The same two electrons leave the zinc and land on the copper ion, so n = 2 mol e− per mole of reaction.
- ΔG° is an area. Energy = charge × voltage. The charge is n × F = 2 × 96,485 C and the height is 1.10 V, so ΔG° = −nFE° = −(2)(96,485 C/mol)(1.10 V) = −212,267 J = −212 kJ/molrxn. 1 C × 1 V = 1 J, so divide by 1000 for kJ.
- Double the equation, double the width. 2Zn + 2Cu2+ moves 4 mol e−, so the block is twice as wide but just as tall: E° stays +1.10 V (intensive) while ΔG° becomes −425 kJ/molrxn (extensive). Never multiply E° by a coefficient.
- Run it backward, flip both signs. Cu + Zn2+ → Cu2+ + Zn has E° = −1.10 V and ΔG° = +212 kJ/molrxn: not thermodynamically favored, K < 1. It only happens if a power supply pushes it (an electrolytic cell). E° > 0, ΔG° < 0 and K > 1 always go together.
- Standard reduction potential (E°)
- The voltage of a half-reaction written as a reduction, measured against the hydrogen electrode (0.00 V) at 1 M, 1 atm, 25 °C. More positive = easier to reduce.
- Standard cell potential (E°cell)
- E°cathode − E°anode. Positive for a galvanic cell, negative for a reaction that has to be driven.
- n
- Moles of electrons transferred per mole of reaction, from the balanced equation. Electrons lost = electrons gained, counted once.
- Faraday constant (F)
- 96,485 C per mole of electrons: the charge of one mole of electrons.
- Thermodynamically favored
- ΔG° < 0, which for a redox reaction means E° > 0 and K > 1. It says nothing about how fast the reaction goes.
- Intensive vs. extensive
- E° is intensive (energy per coulomb, same for any amount). ΔG° is extensive (it scales with n and with the coefficients).
What the exam hands you, and what it doesn't
On the exam already
- ΔG° = −nFE° is on the equations sheet, in the same line as ΔG° = ΔH° − TΔS° = −RT ln K
- The Faraday constant, F = 96,485 C/mol e−, and R = 8.314 J/(mol·K)
- The standard reduction potentials you need, printed in the question itself
- The periodic table and a calculator for every part of the exam
You bring
- E°cell = E°cathode − E°anode, with both values written as reductions
- Which half is the cathode: the one reduced in the reaction as written (for a cell that runs on its own, the higher E°)
- How to find n: balance the electrons between the two half-reactions and count them once
- Units: −nFE° comes out in joules; divide by 1000 before comparing with kJ
- The sign chain: E° > 0 ⇔ ΔG° < 0 ⇔ K > 1 ⇔ thermodynamically favored
Try it: Dip a strip, read the block
Pick a metal strip and an ion for the beaker. As written, the strip is oxidized and the ion is reduced. If the ion's E° is higher, metal plates out and the free-energy block stands above zero; if not, nothing happens and the block hangs below. Then switch to × 2 and watch which way the block grows.
Work it: Will the strip react?
Type each step. Find the cathode for the reaction as written, then E°cell, n and ΔG°, and decide if it is favored. A wrong answer gets a reason, a second miss shows the line. Then try new metals.
How it shows up on the exam
- Calculating E°cell from two given reduction potentials and identifying the anode, the cathode and the direction of electron flow. Expect wrong choices built from adding the potentials, subtracting them backward, or multiplying E° by a coefficient.
- Turning E° into ΔG° with −nFE° (n from the balanced half-reactions, joules to kJ), and linking the sign of E° to ΔG° and K, sometimes with ΔG° = −RT ln K in the same question.
- On free response, "justify" whether a reaction is thermodynamically favorable means a calculated E°cell with its sign, then the link: E° > 0 so ΔG° = −nFE° < 0. "The metal is more reactive" with no E° values does not earn the point.
Find the wrong step
Find ΔG° for Al(s) + 3Ag+(aq) → Al3+(aq) + 3Ag(s). E°: Ag+/Ag = +0.80 V, Al3+/Al = −1.66 V. Click the line with the mistake.
The mistake: n is the electrons in the whole balanced equation, not for one ion. Al → Al3+ + 3e−, and all three are taken by 3Ag+, so n = 3.
ΔG° = −(3)(96,485)(2.46) = −712,059 J = −712 kJ/molrxn
Practice: 3 questions
Original AP-style questions. Every wrong choice is a real trap, and the explanation names it.
An iron nail is placed in 1.0 M CuSO4(aq) at 25 °C. E°: Cu2+/Cu = +0.34 V, Fe2+/Fe = −0.44 V. Which statement is correct?
A is correct. As written, Fe + Cu2+ → Fe2+ + Cu: Cu2+ is reduced, so E°cell = 0.34 − (−0.44) = +0.78 V. A positive E° gives ΔG° = −nFE° < 0, so the reaction is favored and copper plates onto the iron.
B is wrong. Trap: subtracted backward (anode − cathode). Cu2+ is the species reduced here, so its E° goes first.
C is wrong. Trap: the potentials were added. E°cell is a difference, E°cathode − E°anode.
D is wrong. Trap: the lower E° is the half-reaction that runs as oxidation. Iron dissolves; copper is the metal that forms.
Standard reduction potentials: Ag+/Ag +0.80 V, Cu2+/Cu +0.34 V, Zn2+/Zn −0.76 V, Al3+/Al −1.66 V, Mg2+/Mg −2.37 V. With each equation balanced with the smallest whole numbers, which galvanic cell has the most negative ΔG° per mole of reaction?
A is wrong. Trap: picking the biggest voltage and ignoring n. With n = 2, ΔG° = −612 kJ, about half of the Al/Cu2+ value.
B is wrong. Trap: n = 3 here (Al + 3Ag+), so ΔG° = −712 kJ. Al with Cu2+ needs 6 electrons to balance, which wins.
C is wrong. Trap: Ag+ is the strongest oxidizer in the list, but the cell's ΔG° is only −301 kJ (n = 2, 1.56 V).
D is correct. ΔG° = −nFE° depends on n as well as E°. 2Al + 3Cu2+ moves 6 e−: −(6)(96,485)(2.00) = −1158 kJ. Mg/Ag⁺ is −612 kJ (n = 2), Al/Ag⁺ is −712 kJ (n = 3) and Zn/Ag⁺ is −301 kJ (n = 2).
A galvanic cell has ΔG° = −212 kJ/molrxn and transfers 2 mol of electrons per mole of reaction. What is E°cell? (F = 96,485 C/mol e−)
A is wrong. Trap: n was left out. 212,000 ÷ 96,485 = 2.20; divide by 2 mol e− as well.
B is correct. E° = −ΔG° ÷ nF = 212,000 J ÷ (2 × 96,485 C) = +1.10 V. Convert kJ to J first, and a galvanic cell's E° is positive.
C is wrong. Trap: kJ was not changed to J. 212 ÷ 192,970 gives a voltage 1000 times too small.
D is wrong. Trap: sign. ΔG° = −nFE°, so a negative ΔG° gives a positive E°.
How it connects
Ideas from this topic show up again in other topics. These are the links the exam uses most.
Back to your guessFor Zn(s) + Cu2+(aq) → Zn2+(aq) + Cu(s), E°cell = +1.10 V. A student doubles every coefficient: 2Zn + 2Cu2+ → 2Zn2+ + 2Cu. What happens to E° and ΔG°?
Answer: C. E° stays 1.10 V and ΔG° doubles. Voltage is energy per coulomb, so it does not depend on how much reacts. Doubling the equation doubles the electrons moved (n goes from 2 to 4), so ΔG° = −nFE° goes from −212 kJ to −425 kJ per mole of reaction as written.
Quick questions
How do you calculate standard cell potential?
Write both half-reactions as reductions with their E° values. The one reduced is the cathode (for a working galvanic cell, the more positive one). E°cell = E°cathode − E°anode. Do not flip a sign and then also subtract, and do not multiply E° by the coefficients.
How do you find n in ΔG° = −nFE°?
Balance the two half-reactions so the electrons lost equal the electrons gained, then n is that number of electrons per mole of reaction. For Al + 3Ag+, aluminum loses 3 and three silver ions gain 1 each, so n = 3, not 1 and not 6.
Why is E° not multiplied by coefficients but ΔG° is?
E° is energy per coulomb of charge, an intensive property, so a bigger batch pushes each electron just as hard. ΔG° is total energy per mole of reaction as written; doubling the equation doubles n and so doubles ΔG°.
Go deeper
Galvanic and Electrolytic Cells: the full Unit 9 lesson
About 13 minutes of interactive slides on topics 9.8 to 9.9, with step-by-step math, particle drawings, a diagnostic that finds your weak spots, a 50-question bank and AI-scored free response.