AP Chemistry · Unit 9 · Topic 9.10
9.10 Cell Potential Under Nonstandard Conditions
TLDR
E° is the voltage at standard conditions, where Q = 1. Real cells are rarely there, so the voltage follows the Nernst equation, E = E° − (RT/nF) ln Q. If Q < 1 (more reactant than at standard conditions), E is above E°; if Q > 1, E is below E°. As a galvanic cell runs, products build up, Q climbs toward K and E falls, slowly at first (only 0.0592/n V for each factor of 10 in Q at 25 °C). At Q = K, E = 0 and ΔG = 0: the battery is dead, even though reactants are still there.
Guess firstA Zn | Cu cell (Zn + Cu2+ → Zn2+ + Cu) starts with both ions at 1.0 M and reads 1.10 V. It runs until [Cu2+] has fallen to 0.10 M and [Zn2+] has risen to 1.9 M. About what does the voltmeter read now?
Pick one now. The page tells you if you were right at the end, after the picture and the sim show you why.
A is wrong. Trap: E° is fixed, but E is not. E° is the voltage only when Q = 1. Here Q = 19, so E is below E°.
B is wrong. Trap: voltage is not proportional to concentration. It depends on log Q, so a factor of 10 changes E by only 0.0296 V here.
C is wrong. Trap: a cell is dead when Q = K, not when most of a reactant is used. Q = 19 is far below K, so the cell still pushes hard.
D is correct. Q = [Zn2+]/[Cu2+] = 1.9/0.10 = 19. E = 1.10 − (0.0592/2) log 19 = 1.10 − 0.038 = 1.06 V. Even with 90% of the Cu2+ used, E barely moves, because Q is still nowhere near K = 1.6 × 1037. A battery holds its voltage until it is almost spent.
Locked in. Keep reading, the answer is at the end of the page.
The whole topic in one picture
- The equation behind the dial. E = E° − (RT/nF) ln Q is on the equations sheet. At 25 °C, RT/F = 0.0257 V, which is the same as E = E° − (0.0592/n) log Q. Setting E = 0 gives log K = nE°/0.0592 = 2(1.10)/0.0592 = 37.2.
- Fresh cell: Q < 1, E above E°. With 0.0010 M Zn2+ and 1.00 M Cu2+, Q = [Zn2+]/[Cu2+] = 0.0010. ln Q is negative, so E = 1.10 + 0.089 = 1.19 V, more than E°. Less product means a bigger push forward.
- Q = 1: E = E° = 1.10 V. After the cell runs a while, both ions are 0.50 M. That is not standard (1 M), but Q = 1 and ln 1 = 0, so E = E°. Any mixture with Q = 1 reads E°.
- Q = 1.0 × 1010: still 0.80 V. Cu2+ is down to 1.0 × 10−10 M, yet ten powers of ten in Q cost only 10 × 0.0296 = 0.30 V. At 25 °C with n = 2, each factor of 10 in Q lowers E by 0.0296 V, so the voltage stays high until a reactant is almost gone.
- Q = K: E = 0, a dead battery. K = 1.6 × 1037, so the needle reaches 0 only when [Cu2+] is about 6 × 10−38 M. At Q = K, ΔG = −nFE = 0: no net reaction and no current, even with 1.00 M Zn2+ and zinc metal left. A cell with Q > K would run in reverse.
- Nernst equation
- E = E° − (RT/nF) ln Q. Gives the cell potential at the actual concentrations. On the equations sheet.
- E° and E
- E° is the cell potential at standard conditions (1 M, 1 atm, Q = 1). E is the potential of the cell you actually have.
- Reaction quotient Q
- Products over reactants for the cell reaction as written, each raised to its coefficient. Solids and liquids are left out.
- n
- Moles of electrons transferred per mole of reaction, from the balanced half-reactions (2 for Zn + Cu2+).
- Concentration cell
- Both half-cells use the same metal and ion at different concentrations. E° = 0, but E > 0 until the concentrations are equal.
- Dead battery
- A cell at equilibrium: Q = K, E = 0 and ΔG = 0. Reactants can still be present.
What the exam hands you, and what it doesn't
On the exam already
- The Nernst equation, E = E° − (RT/nF) ln Q
- ΔG° = −nFE° and ΔG° = −RT ln K, with F = 96,485 C/mol e− and R = 8.314 J/(mol·K)
- Standard reduction potentials are given in the question when you need them (there is no table on the sheet)
- A calculator for every part of the exam
You bring
- Writing Q for the cell reaction: products over reactants, coefficients as exponents, solids left out
- Finding n from the balanced half-reactions, and keeping T in kelvin (298 K)
- The direction rule: Q < 1 gives E > E°, Q = 1 gives E = E°, Q > 1 gives E < E°, Q = K gives E = 0
- ln and log are different: (RT/F) ln Q = 0.0592 log Q at 25 °C. The 0.0592 form is not on the sheet
- Le Chatelier as a shortcut: adding a reactant or removing a product raises E
Try it: Slide Q, watch the voltmeter
Pick a cell and drag Q along its log scale. The center-zero voltmeter swings, the electrons change direction, and the beakers show the concentrations that give that Q. Find Q = 1 (E = E°), then push Q past K.
Work it: A concentration cell from first volt to dead
Same metal on both sides, different concentrations. Type each step: E°, the anode, Q, the starting voltage and the concentrations when the cell is dead. New numbers bring other metals and concentrations.
How it shows up on the exam
- Predicting the direction: a change in concentration (dilute a half-cell, add a product, precipitate an ion) moves Q, and you say whether E goes up or down. This is the most common form.
- Calculating E with the Nernst equation from E°, n and the concentrations, or working back from a measured E to Q. Watch ln versus log and the value of n.
- On free response: "Explain why the cell potential decreases as the cell operates" wants Q rising toward K and E falling to 0 at equilibrium, not "the reactants run out". "Justify" a direction by naming the species, how Q changes, and the Nernst link.
Find the wrong step
A Zn | Cu cell has [Zn2+] = 0.10 M and [Cu2+] = 1.0 M at 25 °C. Find E. Click the line with the mistake.
The mistake: Zn → Zn2+ + 2e− and Cu2+ + 2e− → Cu: two electrons move for each Zn that reacts, so n = 2. Using n = 1 doubles the correction.
E = 1.10 − (0.02568 ÷ 2)(ln 0.10) = 1.10 + 0.030 = 1.13 V, above E° because Q < 1.
Practice: 3 questions
Original AP-style questions. Every wrong choice is a real trap, and the explanation names it.
A galvanic cell runs Ni(s) + 2Ag+(aq) → Ni2+(aq) + 2Ag(s) with both solutions at 1.0 M. Which change makes the cell potential larger?
A is correct. Ag+ is a reactant, so raising [Ag+] lowers Q = [Ni2+]/[Ag+]2. With Q below 1, ln Q is negative, so −(RT/nF) ln Q is positive and E rises above E°.
B is wrong. Trap: Ni2+ is a product. More product raises Q, so E falls.
C is wrong. Trap: solids are not in Q, and E does not depend on electrode size. A bigger electrode can carry more current at the same voltage.
D is wrong. Trap: dilution halves both, but [Ag+] is squared. Q = 0.5 ÷ 0.52 = 2, so Q rises and E falls.
For the Zn | Cu cell (n = 2) at 25 °C, a student measures E at many concentrations and graphs E against ln Q. The points fall on a straight line. What are its slope and its intercept at ln Q = 0?
A is wrong. Trap: that is −RT/F with n = 1. Two electrons move per Zn, so divide by 2.
B is wrong. Trap: that is the slope against log Q (0.0592 ÷ 2). The graph uses ln Q.
C is correct. E = E° − (RT/nF) ln Q is a line in ln Q. The slope is −RT/nF = −(8.314)(298) ÷ [(2)(96,485)] = −0.0128 V, and at ln Q = 0 (Q = 1), E = E° = 1.10 V.
D is wrong. Trap: E = 0 at Q = K, not at Q = 1. At ln Q = 0 the cell reads E°.
The cell Cu(s) + 2Ag+(aq) → Cu2+(aq) + 2Ag(s) has E° = +0.46 V. At 25 °C it reads +0.40 V. What is Q?
A is wrong. Trap: n = 1 was used. Cu → Cu2+ moves 2 electrons, so n = 2 and ln Q doubles.
B is correct. 0.40 = 0.46 − (0.02568 ÷ 2) ln Q, so ln Q = (0.06)(2) ÷ 0.02568 = 4.67 and Q = e4.67 = 1.1 × 102. E below E° means Q > 1, which checks.
C is wrong. Trap: a sign slip gave 1/Q. E is below E°, so Q must be greater than 1.
D is wrong. Trap: that is ln Q. Take e4.67 to get Q.
How it connects
Ideas from this topic show up again in other topics. These are the links the exam uses most.
Back to your guessA Zn | Cu cell (Zn + Cu2+ → Zn2+ + Cu) starts with both ions at 1.0 M and reads 1.10 V. It runs until [Cu2+] has fallen to 0.10 M and [Zn2+] has risen to 1.9 M. About what does the voltmeter read now?
Answer: D. About 1.06 V, a little below 1.10 V. Q = [Zn2+]/[Cu2+] = 1.9/0.10 = 19. E = 1.10 − (0.0592/2) log 19 = 1.10 − 0.038 = 1.06 V. Even with 90% of the Cu2+ used, E barely moves, because Q is still nowhere near K = 1.6 × 1037. A battery holds its voltage until it is almost spent.
Quick questions
What does the Nernst equation tell you?
It gives the cell potential at the concentrations you actually have: E = E° − (RT/nF) ln Q. When Q = 1 it gives E°; when Q = K it gives 0. On the AP exam it is on the equations sheet.
Does increasing concentration increase cell voltage?
It depends on which side. Raising a reactant concentration lowers Q and raises E. Raising a product concentration raises Q and lowers E. The size of the change is small: 0.0592/n V per factor of 10 at 25 °C.
Why is a dead battery at 0 V if it still has chemicals in it?
A battery is dead when its reaction reaches equilibrium, Q = K. Then ΔG = 0 and E = 0, so there is no net push for electrons, even though reactants and products are both still present.
Go deeper
Nonstandard Cells and Electrolysis: the full Unit 9 lesson
About 13 minutes of interactive slides on topics 9.10 to 9.11, with step-by-step math, particle drawings, a diagnostic that finds your weak spots, a 50-question bank and AI-scored free response.